Zigzag transformer
I have found results from800+products and200+suppliers aboutZigzag transformer
22.9kv 60Hz/50Hz Zigzag Transformer with Netural Grounding Resistor
Oil-Immersed Earthing Transformer with Zig-Zag Winding and Neutral Point Access
Advanced Air-Cooled 100kVA Transformer for Zigzag Winding Systems
Zig Zag Connected Grounding Transformer for Neutral Earthing
34.5kv-200A/10s, Zig - Zag - N, Oil Type Earthing Transformer
1600kVA 66kv 10kv Zig Zag Earthing Transformer Oil Immersed High Voltage Neutral Grounding Station
500kVA 10kv 0.4kv Zig Zag Transformer Dry Type Cast Resin Neutral Grounding Earthing Transformer
2500kVA 30kv 10kv Zigzag Grounding Transformer Dry Type Cast Resin E3-C2-F1 IEC Standard Export
630kVA Zig Zag Transformer 33kv/0.415kv Neutral Grounding Transformer for Utility Network
Indoor Dry Type Zig Zag Grounding Transformer 500kVA 20kv with Zero Sequence Impedance
Zig-Zag Earthing Transformer with Neutral Grounding Resistor Ngr System for Power Grid
Zig Zag Neutral Grounding Transformer Manufacturer for Export - IEC 60076 Dry Type
Iutdoor Dry Type Zig Zag Neutral Grounding Transformer 400kVA 35kv C4 Anti-Corrosion
Ring Structure: Epoxy Casting Type Zikai Wooden Case Zigzag Dry Transformer Coil
Separated Winding Coil Material: Aluminum/Copper Zikai Industrial Control Dry Transformer Zigzag
Power Frequency Nominal Capacity: 30kVA-3150kVA Zikai Fully Sealed Dry Transformer Zigzag
Circular Coil Material: Aluminum/Copper Zikai Wooden Case Zigzag Dry Transformer Cooling Fan
Power Structure: Epoxy Casting Type Zikai Wooden Case Solar Dry Transformer Zigzag
Instrument Connection Method: Yyn0/Dyn11 Zikai Wooden Case Zigzag 800 Dry Transformer
Coil Material: Aluminum/Copper Connection Method: Yyn0/Dyn11 Split Core Current Dry Transformer Zigzag
Sourcing guidance for Zigzag Transformer
What are the primary functions and usage scenarios for a Zigzag Transformer?
A Zigzag Transformer is primarily used to provide a neutral point for grounding in an ungrounded three-phase system. Its unique winding structure allows it to trap zero-sequence currents while offering low impedance to ground faults. Common scenarios include wind farms, solar power plants, and industrial power systems where stabilizing the neutral point and detecting earth faults are critical for system protection.
What key technical specifications should B2B buyers prioritize?
Buyers must specify the Short-Time Current Rating (e.g., 100A to 2000A) and the Duration (typically 10s, 30s, or 60s) the transformer can withstand a fault. Additionally, evaluate the Zero-Sequence Impedance, as this determines the fault current level. Ensure the Insulation Class (Class H or F) and Cooling Method (ONAN or KNAN) align with the installation environment's temperature and safety requirements.
Which international compliance standards are mandatory for Zigzag Transformers?
For global trade, ensure the product complies with IEC 60076-6 (Reactors) or IEEE C57.12.00 standards. For the European market, CE marking and EcoDesign Directive compliance are essential. If exporting to North America, UL listing or CSA certification is often a prerequisite for insurance and local grid connection.
How can buyers verify the quality and durability of the transformer core and windings?
Request documentation confirming the use of high-permeability cold-rolled grain-oriented (CRGO) silicon steel to minimize no-load losses. Windings should ideally be made of 99.9% pure electrolytic copper. Ask for Type Test Reports, including impulse voltage tests and temperature rise tests, conducted by accredited third-party labs like KEMA or TUV.
Cross-Border Procurement & Risk Management for Industrial Transformers
How can I mitigate the risk of damage during international shipping?
Transformers are heavy and sensitive to moisture. Insist on vacuum-sealed moisture-proof packaging and seaworthy wooden crates (IPPC certified). For large units, require the installation of Impact Recorders (G-force sensors) and Tilt Indicators on the crate to monitor handling during transit. Ensure the Incoterms used are CIF or CIP to include comprehensive insurance coverage.
What are the best strategies for negotiating with suppliers on Made-in-China.com?
Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for a longer warranty period (24-36 months) and the inclusion of critical spare parts (like bushings or gaskets). For bulk orders, request a staged payment plan (e.g., 30% deposit, 60% after successful FAT/Factory Acceptance Test, 10% after arrival) to maintain leverage over quality.
How do I ensure transaction security and supplier legitimacy?
Utilize the Secured Trading Service on Made-in-China.com to protect your payments. Before finalizing, conduct a Factory Audit (either in-person or via a third-party service like SGS) to verify the supplier's ISO 9001/14001 certifications and actual production capacity. Check their export history to see if they have experience with your specific country's grid requirements.
What should be considered regarding international trade policies and customs?
Verify the HS Code (typically 850433 or 850434) to calculate accurate import duties and VAT. Be aware of Anti-Dumping Duties that some regions (like the EU or USA) may impose on electrical steel or transformers from specific origins. Ensure all Technical Manuals and Nameplates are provided in the destination country's official language to avoid customs clearance delays.