Chlorine meter
I have found results from30000+products and10000+suppliers aboutChlorine meter
Boqu Dcsg-2099 pH Conductivity Dissolved Oxygen Residua Chlorine Turbidity Multi Parameter Meter
Boqu Cl-2059A Factory Price Chlorine Residue Meter in Water with RS485 and 4-20mA Output
Chlorine Ion Meter Water Quality Analysis Industrial Meter (PFG-3085)
Cl-2059A Online Residual Chlorine Meter with High Accuracy
Best Selling 6 in 1 pH/TDS/Ec/ORP OEM pH Chlorine Meter
Industrial Online Free Residual Chlorine Meter Analyzer Transmitter
T4055 Online Residual Chlorine Meter with Sensor 4-20mA RS485
High Quality Online Chlorine Analyzer Free Chlorine Meter for Swimming Pool
2ppm Industrial Online Free Chlorine Meter Controller for Water Treatment
Industrial Online Free Chlorine FCL Meter SC6000FCL
Industrial Online Residual Chlorine Meter Controller with Residual Chlorine Test Sensor
Online pH Chlorine Meter 2 in 1 Residual Chlorine pH Controller for Secondary Water Supply Analysis
Apure Online Water Analyser pH and Chlorine Tester/Controller Meter & Sensor with 4-20mA
Industrial Online Residual Chlorine Meter with Sensor
Apure Online 4-20mA RS485 Residual Free Chlorine Controller Meter with Sensor
Apure Industrial Online 4-20mA Residual Chlorine Meter Controller Analyzer/Chlorine Senosr/Chlorine Probe
Digital Residual Chlorine Meter for SPA and Pool Care
Portable Conductivity/Dissolved Oxygen/Free Chlorine Meter Meter
Online Water Quality Monitoring Free Residual Chlorine Meter with Constant Voltage
Sourcing guidance for Chlorine Meter
What are the key technical specifications to consider when selecting a professional chlorine meter?
Buyers should prioritize the measurement range (typically 0-10 mg/L for portable units) and resolution (ideally 0.01 mg/L). Ensure the device uses DPD (Diethyl-p-phenylenediamine) colorimetric methods or amperometric sensors for high accuracy. Additionally, look for Automatic Temperature Compensation (ATC) to ensure readings remain stable across different environmental conditions, and a large LCD display with backlighting for field use.
Which international compliance standards are essential for chlorine meters in industrial and laboratory settings?
For global trade, the device must meet CE (European Conformity) and RoHS standards for electronic safety. For water quality monitoring, verify if the meter aligns with EPA-approved methods (specifically Method 330.5 or 4500-Cl G). If the product is intended for food and beverage industries, IP67 waterproof rating is crucial to prevent damage from splashes and high-humidity environments.
How do I evaluate the economic feasibility and long-term maintenance costs of these devices?
Beyond the initial purchase price, calculate the cost per test, which includes the price of reagent pillows, tablets, or liquid kits. Opt for suppliers on Made-in-China.com who offer bulk reagent discounts. Check the sensor lifespan (typically 6-24 months for electrochemical types) and the availability of calibration buffers, as frequent calibration is necessary to maintain professional-grade precision.
What are the primary usage scenarios and functional differences between portable and benchtop chlorine meters?
Portable meters are designed for on-site testing in swimming pools, cooling towers, and water treatment plants, emphasizing durability and battery life. Benchtop meters are suited for laboratory environments, offering higher data storage capacity, USB/RS232 interfaces for PC connectivity, and multi-parameter testing capabilities (e.g., pH, ORP, and Chlorine simultaneously).
Cross-Border Procurement Strategy for Chlorine Meters
What are the common risks when importing precision electronic instruments like chlorine meters?
The primary risks include calibration drift during transit and damage to sensitive glass electrodes. To mitigate this, require the supplier to use anti-static and shock-absorbent packaging. Furthermore, ensure the lithium batteries (if included) comply with UN38.3 air transport regulations to avoid customs delays or seizures.
How can I negotiate effectively with suppliers on Made-in-China.com for bulk orders?
Request a sample unit for lab validation before committing to a large volume. Negotiate based on tiered pricing (e.g., 50, 100, and 500 units) and ask for extended warranties (18-24 months) instead of just price cuts. High-quality suppliers are often willing to provide OEM branding/logo printing for free if the order meets a specific threshold.
What transaction security measures should be taken for international payments?
Always use Secured Trading Services provided by the platform to ensure funds are only released after confirmation of receipt and inspection. For large transactions, consider Letter of Credit (L/C) or Escrow services. Avoid direct wire transfers to private accounts; always ensure the beneficiary name matches the company name on the business license.
What is the best shipping method for sensitive water testing equipment to ensure safety and speed?
For high-value precision instruments, Air Freight or Express Couriers (DHL/FedEx/UPS) are recommended to minimize handling time and environmental exposure. Ensure the supplier provides a Certificate of Origin and a detailed HS Code (typically 9027.80) classification to streamline customs clearance and potentially reduce import tariffs.