SourcingAI

Emergency panel light

I have found results from100000+products and70000+suppliers aboutEmergency panel light

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Handed Type
Type: Ceiling
Lamp Body Material: Aluminum Alloy
IP Rating: IP66
Irradiated Area: 15-30m²
Input Voltage: 220v
Color Temperature: Warm White
Emitting Color: RGB
LED Chips Brand: Osram
Certification: CCC
Usage: Fire Lights
Emergency Time: 3-4h
Installation: Wall-hanging
Operation Mode: Non-maintained
Battery Type: Ni-Cd Battery
Cold Rolled Steel Sheet
Light Source: LED Lamp
Light Type: Solar
Technics: Painted Matte
Charging Time (H): 4
With Light Source
Projection Distance: 18-25m
Application: Park
Bulb Type: LED
Color Temperature(CCT): Warm White
Power Source: Solar Power
Housing Material: PC
Power: 6W-10W
Illumination Time: 12h
Cell Type: Ni-MH Battery
Voltage: 3-6V
Dimmable: With Dimmable
Appearance: Square
Base Material: Plastic
Beam Angle: 120°
Condition: New
Style: Countryside
Lighting Area: 1-3m^2
Warranty: 1 YEAR
Light Source Type: LED
Folded: Unfolded
Specification: Mini
Color: White
Applicable Places: Conference Room
Warranty Period: 2 Years
Light Range: <50m
Lighting Period (H): 4
Power Supply: Rechargeable Battery
Brightness Level: 2,000-5,000 Lumens
Mount Type: Surface
Lamp Body Material: Aluminum
Lamp Body Material: Plastic
IP Rating: IP65
IP Rating: IP67
IP Rating: IP55
15-30 Square Meters
Color Temperature: Cool White
Emitting Color: Cool White
Emitting Color: Red
Emitting Color: White
Emitting Color: Warm White
Emitting Color: Yellow
LED Chips Brand: Epistar
Certification: CE
Certification: RoHS
Certification: Reach
Certification: ISO
Certification: SAA
Certification: ISO9001
Certification: VDE
Certification: SASO
Usage: Street
Usage: Camping
Usage: Emergency Lighting
Usage: Garden
Battery Type: Lead-acid
Battery Type: Ni-Cd
Material: Plastic
Material: Monocrystalline Silicon
Material: Aluminum
Material: ABS
Light Source: LED
Light Type: LED
Technics: Drawbench
Technics: Electroplating
Charging Time (H): 6
Charging Time (H): 10
Charging Time (H): 8
Without Light Source
Projection Distance: 12-18m
Application: Square
Application: Factory
Application: Industrial
Application: Garden
Application: Home
Application: Commercial
Housing Material: Acrylic
Housing Material: Aluminium
Power: ≤5W
Power: 11W-15W
Illumination Time: 10h
Voltage: 120V
Voltage: 200-240V
Voltage: 90V-260V
Voltage: 12/24V
Dimmable: Without Dimmable
Base Material: Iron
Style: Contemporary

Sourcing guidance for Emergency Panel Light

What are the key technical specifications to consider when sourcing Emergency Panel Lights?

Buyers should prioritize high-efficiency LED chips (minimum 100lm/W) and lithium iron phosphate (LiFePO4) batteries, which offer longer lifecycles and better thermal stability than traditional Ni-Cd batteries. Ensure the emergency duration is at least 90 to 180 minutes depending on local fire safety codes. Additionally, look for integrated self-test functions that automatically perform monthly and annual checks to ensure operational readiness.

Which compliance standards and certifications are mandatory for international markets?

For the European market, CE-LVD, CE-EMC, and RoHS are essential, along with EN 60598-2-22, which specifically governs emergency lighting requirements. For the North American market, UL 924 (Emergency Lighting and Power Equipment) is the gold standard. Ensure the supplier provides valid test reports from accredited third-party labs like TUV, SGS, or Intertek to avoid customs clearance issues.

How does the 'Switching Time' affect the performance of the emergency light?

The switching time (transfer time) should ideally be less than 0.5 to 1 second. In critical environments like hospitals or high-traffic commercial zones, a rapid transition from mains power to battery power is vital for safety. Verify that the driver is compatible with both constant current output and emergency modules to prevent flickering during the switch.

What are the common usage scenarios and installation requirements for these products?

Emergency panel lights are primarily used in office buildings, hospitals, schools, and shopping malls. Buyers must choose between recessed, surface-mounted, or suspended installations based on the ceiling type. For high-humidity areas like underground parking lots, ensure the product has an IP44 or higher ingress protection rating to prevent moisture damage to the internal circuitry.

Cross-Border Procurement Risks and Strategies

How can I mitigate the risk of battery degradation during long-distance shipping?

Batteries are sensitive to temperature and time. Require the supplier to use freshly manufactured battery cells (less than 3 months old) and ensure they are charged to 30-50% before shipping. Request UN38.3 certification and MSDS reports to comply with international air and sea freight regulations for hazardous materials.

What is the best strategy for negotiating with suppliers on Made-in-China.com?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for extended warranties (3-5 years) on the emergency driver and battery, as these are the most common failure points. For bulk orders, ask for 1-2% spare parts (FOC) to be included in the shipment to handle immediate replacements for minor defects.

How do I ensure transaction security and quality control before final payment?

Utilize Secured Trading Services provided by Made-in-China.com to protect your funds. Always hire a third-party inspection agency to conduct a Pre-Shipment Inspection (PSI). The inspector should specifically test the emergency function by cutting the power and measuring the light output and duration to ensure it matches the agreed-upon specifications.

What shipping methods are recommended for electronic products containing batteries?

For large volumes, Sea Freight (FCL/LCL) is the most economical, but you must ensure the carrier accepts Class 9 dangerous goods if the batteries are integrated. For urgent samples, use specialized couriers (like DG-certified lines). Always ensure the packaging includes anti-static materials and robust outer cartons to prevent physical damage during transit.

Related queries